        UL 94 Horizontal and vertical flame test apparatus BND-SPR

        The horizontal and vertical burning test mainly refers to UL 94-2006, IEC 60695-11-4, IEC 60695-11-3, GB/T5169-2008 series and other standards, using Bunsen burner of specified size and specific gas source (Methane or propane), according to a certain flame height and a certain flame angle, the test sample in a horizontal or vertical state is regularly burned several times, and its flammability is evaluated by the duration and burning length of the test sample‘s ignition and burning. Sex and fire hazard.
        Description

        Product Description:

        Name:UL 94 Horizontal and vertical flame test apparatus

        Type:BND-SPR


        The Basic introduction of the flame tester:

        1. The horizontal and vertical burning test mainly refers to UL 94-2006, IEC 60695-11-4, IEC 60695-11-3, GB/T5169-2008 series and other standards, using Bunsen burner of specified size and specific gas source (Methane or propane), according to a certain flame height and a certain flame angle, the test sample in a horizontal or vertical state is regularly burned several times, and its flammability is evaluated by the duration and burning length of the test sample's ignition and burning. Sex and fire hazard.

        2. HVR-4 horizontal and vertical combustion tester is mainly used for grading assessment of the flammability of V-0, V-1, V-2, HB, and 5V materials. It is suitable for the research, production and quality inspection departments of electrical and electronic products and their components such as lighting equipment, low-voltage electrical appliances, household appliances, machine tool electrical appliances, motors, power tools, electronic instruments, electrical meters, electrical connectors and accessories. Used in insulation materials, engineering plastics or other solid combustible materials industries.


        Technical Parameter of flame test:

        Model

        BND-SPR   Horizontal vertical flame tester

        Kinds

         500W(5V class )

         50W(HB/V class)

        Test Flame

        500W(burning test for V-0,V-1,V-2  classification)

        50W(burning test for V-0,V-1,V-2 classification)

        Burner Tube

        Internal diameter: Φ 9.5mm±0.3mm

        Internal diameter: Φ 9.5mm±0.3mm, 

        Burning Angle

        0°,20°,45°

        0°,20°,45°

        Thermocouple

        Type K (Ni/Cr - Ni/Al)

        Type K (Ni/Cr - Ni/Al)

        Thermocouple Size 

        0.5 mm

        0.5 mm

        Standard Copper Block 

        9mm±0.01mm,

        weight:10g±0.05g before drilling.  

        5.5mm±0.01mm,

        weight:76g±0.01g before drilling.

        Time for Temperature to Increase

        From 100°C±5°C to 700°C±3°C; 54s±2s (preset)

        From 100°C±5°C to 700°C±3°C;

        44s±2s (preset)

        Gas Flow

        965±32ml/min

        105±10ml/min

        Gas Supply

        methane,min.98% purity

        methane,min.98% purity

        water-column 

        125m±5mm

        ‹10mm

        Test  Time

        54±2s

        44±2s

        Flame Height Indicator

        40±1mm

        20±1mm

        Volume Of Chamber

        >0.5m³, black interior

        >0.5m³, black interior

        Conform to standard

        UL94,IEC60695-11-3,IEC60695-11-20

        UL94,IEC60695-11-4,IEC60695-11-10