        IK & IP Testing for Lighting Products

        Ratings that demonstrate the degree of Impact Protection (IK) and Ingress Protection (IP) are critical for street, roadway and other lighting products. IP ratings are required per IEC/EN 60598-2-3 for all roadway and street applications. IK ratings are required in specific applications when high impact glass provides protection for the enclosed lamp.

        Standards

        IEC 62262 specifies the way enclosures should be tested for IK ratings which are defined as the level of protection the enclosures provided against external mechanical impacts. IEC 60598-1 (IEC 60529) specifies the test method used to classify and rate the degree of protection an enclosure provides against intrusion of various sized solid objects from fingers and hands to fine dust and the protection against water intrusion from falling drops to a high pressure water jet. IEC 60598-2-3 is the International Standard for Luminaires for Road and Street Lighting.

        UL offers complete testing and certification services for street and roadway luminaires to IEC 60598-2-3

        IK ratings are defined as IKXX, where “XX” is a number from 00 to 10 indicating the degrees of protection provided by electrical enclosures (including luminaires) against external mechanical impacts. The IK rating scale identifies the ability of an enclosure to resist impact energy levels measured in joules (J). IEC 62262 specifies how the enclosure must be mounted for testing, the atmospheric conditions required, the quantity and distribution of the test impacts and the impact hammer to be used for each level of IK rating.

        Degrees if protection again external mechanical impacts

        IK00

        IK01

        IK02

        IK03

        IK04

        IK05

        IK06

        IK07

        IK08

        IK09

        IK10

        Non-protected

        0.14J

        0.2J

        0.35J

        0.5J

        0.7J

        1J

        2J

        5J

        10J

        20J

        1.jpg


        IP ratings are defined as IPXX where the first X indicates the degree of protection against solid objects and the second X indicates the degrees of protection against water. A luminaire or lighting component with a rating of IP66 is dust-tight and protected against powerful water jets as described in IEC 60598-1 (IEC 60529).]

        Degrees if protection again solid objects

        IP0X

        Non-protected

        IP1X

        50mm diameter and greater

        IP2X

        12.55mm diameter and greater

        IP3X

        2.5mm diameter and greater

        IP4X

        1.0mm diameter and greater

        IP5X

        Dust-protected

        IP6X

        Dust-tight

        2.jpg

        Degrees if protection again water

        IP0X

        Non-protected

        IP1X

        Vertically falling water drops

        IP2X

        Vertically falling water drops with enclosure tilted

        IP3X

        Spraying water

        IP4X

        Splashing water

        IP5X

        Water jets

        IP6X

        Powerful water jets

        IP7X

        Temporary immersion

        IP8X

        Continuous immersion